For which elements do the maximum permitted thermal transmittance values apply?

Answer

Informational English translation. Machine translated; not independently reviewed.

For elements of the thermal envelope of the building and elements between two adjacent thermal zones, according to Table 3.4.1.3 of Annex 3. The same values also apply to internal building structures bordering rooms in which the air temperature at the design outdoor temperature is below 12 degrees Celsius.

Note: Select the appropriate row of Table 3.4.1.3. For a new building, an external wall has Umax 0,30, and a wall adjoining an unheated space 0,40 W/(m²K); for an existing building after works, 0,40 and 0,55 respectively. Intermediate floor structures have separate rows 16 and 17. Do not automatically copy the value for an external wall.

Original Serbian quotation

„Ове вредности се примењују и на унутрашње грађевинске конструкције које се граниче са просторијама у којима је температура ваздуха при пројектној температури спољашњег ваздуха (период грејања) нижа од 12”
Informational English translation of the quotation
These values also apply to internal building structures bordering rooms in which the air temperature at the design outdoor air temperature (heating period) is below 12

Official source ↗

Regulation
Pravilnik o energetskoj efikasnosti zgrada
Article
Art. 10
Official gazette
Sl. glasnik RS, br. 61/2011
Topic
Procedures and documentation

Informational finding. An AI check is not legal or professional confirmation that the rule applies to your building. Check the full article and current official gazette.